        小(xiao)型恒溫恒濕(shi)(shi)(shi)箱(xiang)(xiang)又稱桌上(shang)型恒溫恒濕(shi)(shi)(shi)試驗箱(xiang)(xiang)或迷你型恒溫恒濕(shi)(shi)(shi)箱(xiang)(xiang),除了使用(yong)(yong)人(ren)員正確(que)的(de)按操作(zuo)(zuo)流(liu)程操作(zuo)(zuo)外,還應(ying)該要(yao)對結(jie)(jie)構(gou)有(you)(you)所了解(jie)。小(xiao)型恒溫恒濕(shi)(shi)(shi)試驗箱(xiang)(xiang)的(de)結(jie)(jie)構(gou)是由風(feng)循(xun)環(huan)系(xi)(xi)統、制(zhi)冷系(xi)(xi)統、加(jia)(jia)(jia)溫系(xi)(xi)統及控(kong)濕(shi)(shi)(shi)系(xi)(xi)統所組成(cheng)的(de)。而這些系(xi)(xi)統的(de)存在直接(jie)與試驗箱(xiang)(xiang)價格(ge)的(de)高低有(you)(you)著密切的(de)關系(xi)(xi)。風(feng)循(xun)環(huan)系(xi)(xi)統一般采(cai)用(yong)(yong)的(de)是可調節送風(feng)方(fang)(fang)向(xiang)的(de)結(jie)(jie)構(gou),加(jia)(jia)(jia)濕(shi)(shi)(shi)系(xi)(xi)統有(you)(you)采(cai)用(yong)(yong)鍋(guo)爐(lu)加(jia)(jia)(jia)濕(shi)(shi)(shi)的(de)和(he)表面(mian)蒸(zheng)發兩種。降溫、去濕(shi)(shi)(shi)系(xi)(xi)統采(cai)用(yong)(yong)的(de)是空調工況制(zhi)冷結(jie)(jie)構(gou)。加(jia)(jia)(jia)熱(re)系(xi)(xi)統采(cai)用(yong)(yong)的(de)是電熱(re)鰭片加(jia)(jia)(jia)熱(re)和(he)電爐(lu)絲直接(jie)加(jia)(jia)(jia)熱(re)二種結(jie)(jie)構(gou),溫濕(shi)(shi)(shi)度(du)測試方(fang)(fang)法采(cai)用(yong)(yong)干濕(shi)(shi)(shi)球測試方(fang)(fang)法,也有(you)(you)用(yong)(yong)濕(shi)(shi)(shi)度(du)傳感器直接(jie)測量方(fang)(fang)法。控(kong)制(zhi)和(he)顯示(shi)操作(zuo)(zuo)界面(mian)采(cai)用(yong)(yong)溫濕(shi)(shi)(shi)度(du)分開獨(du)立和(he)溫濕(shi)(shi)(shi)度(du)組合控(kong)制(zhi)器等方(fang)(fang)式(shi)。

   KOWIN小型恒(heng)溫(wen)(wen)(wen)(wen)恒(heng)濕(shi)箱在(zai)做高溫(wen)(wen)(wen)(wen)試(shi)驗中,如果溫(wen)(wen)(wen)(wen)度(du)變化達不到試(shi)驗溫(wen)(wen)(wen)(wen)度(du)值(zhi)時(shi),可(ke)以(yi)檢查(cha)(cha)電器(qi)系統,逐漸(jian)一(yi)排除故障(zhang)。如溫(wen)(wen)(wen)(wen)度(du)升得很(hen)慢(man),那(nei)(nei)就要查(cha)(cha)看(kan)風循(xun)環系統,看(kan)一(yi)下風循(xun)環的調節檔板是否開啟正常(chang),反之(zhi),就檢查(cha)(cha)風循(xun)環的電機運(yun)轉是否正常(chang)。如溫(wen)(wen)(wen)(wen)度(du)過沖厲害那(nei)(nei)么就需要整(zheng)定PID的設(she)置(zhi)參(can)數。如果溫(wen)(wen)(wen)(wen)度(du)直接上升,過溫(wen)(wen)(wen)(wen)保護,那(nei)(nei)么,控制(zhi)器(qi)出(chu)故障(zhang),須更換控制(zhi)儀表。

    低溫達不到試(shi)驗的(de)指(zhi)標,那就(jiu)(jiu)要觀察(cha)溫度(du)的(de)變化,是(shi)溫度(du)降的(de)很(hen)慢,還是(shi)溫度(du)到一定值后(hou)溫度(du)有回升的(de)趨勢,前者就(jiu)(jiu)要檢查(cha)一下,做(zuo)低溫試(shi)驗前是(shi)否將(jiang)工(gong)作(zuo)室(shi)烘干,使(shi)工(gong)作(zuo)室(shi)保(bao)持干燥后(hou)再將(jiang)試(shi)驗樣(yang)(yang)品放入工(gong)作(zuo)室(shi)內(nei)再做(zuo)試(shi)驗,工(gong)作(zuo)室(shi)內(nei)的(de)試(shi)驗樣(yang)(yang)品是(shi)否放置的(de)過多,使(shi)工(gong)作(zuo)室(shi)內(nei)的(de)風不能充分循環,在(zai)排除上述(shu)原因后(hou),就(jiu)(jiu)要考慮是(shi)否是(shi)制冷系(xi)統(tong)中的(de)故障了(le),如果是(shi)這(zhe)樣(yang)(yang)的(de)話(hua)那么就(jiu)(jiu)要請廠家專業(ye)人(ren)員(yuan)進行檢修了(le)。

    在做(zuo)濕(shi)(shi)(shi)(shi)(shi)熱(re)試(shi)(shi)驗中(zhong)(zhong),出現(xian)實際濕(shi)(shi)(shi)(shi)(shi)度會達到(dao)100%或者(zhe)實際濕(shi)(shi)(shi)(shi)(shi)度與目(mu)標濕(shi)(shi)(shi)(shi)(shi)度相差很大(da)(da),數(shu)值低得很多,前者(zhe)的(de)(de)(de)(de)現(xian)象(xiang)(xiang):可(ke)能是(shi)濕(shi)(shi)(shi)(shi)(shi)球傳感器(qi)(qi)上(shang)(shang)(shang)的(de)(de)(de)(de)紗布(bu)干燥(zao)引起,那就(jiu)要(yao)檢(jian)查(cha)濕(shi)(shi)(shi)(shi)(shi)球傳感器(qi)(qi)的(de)(de)(de)(de)水(shui)(shui)(shui)槽中(zhong)(zhong)是(shi)否(fou)(fou)(fou)缺水(shui)(shui)(shui),水(shui)(shui)(shui)槽中(zhong)(zhong)的(de)(de)(de)(de)水(shui)(shui)(shui)位(wei)(wei)是(shi)由(you)一水(shui)(shui)(shui)位(wei)(wei)控(kong)(kong)(kong)制(zhi)(zhi)器(qi)(qi)自(zi)動控(kong)(kong)(kong)制(zhi)(zhi)的(de)(de)(de)(de),查(cha)水(shui)(shui)(shui)位(wei)(wei)控(kong)(kong)(kong)制(zhi)(zhi)器(qi)(qi)供水(shui)(shui)(shui)系統(tong)(tong)是(shi)否(fou)(fou)(fou)供水(shui)(shui)(shui)正常,水(shui)(shui)(shui)位(wei)(wei)控(kong)(kong)(kong)制(zhi)(zhi)器(qi)(qi)工(gong)(gong)作是(shi)否(fou)(fou)(fou)正常。另一種可(ke)能就(jiu)是(shi)濕(shi)(shi)(shi)(shi)(shi)球紗布(bu)因(yin)使用時間長,或供水(shui)(shui)(shui)水(shui)(shui)(shui)質純(chun)凈度的(de)(de)(de)(de)原因(yin),會使紗布(bu)變硬(ying),使紗布(bu)無法吸收水(shui)(shui)(shui)份而干燥(zao),只要(yao)更換或清洗紗布(bu)即可(ke)排除以(yi)上(shang)(shang)(shang)現(xian)象(xiang)(xiang)。后者(zhe)的(de)(de)(de)(de)現(xian)象(xiang)(xiang)主(zhu)要(yao)是(shi)加(jia)(jia)濕(shi)(shi)(shi)(shi)(shi)系統(tong)(tong)不(bu)工(gong)(gong)作,查(cha)看加(jia)(jia)濕(shi)(shi)(shi)(shi)(shi)系統(tong)(tong)的(de)(de)(de)(de)供水(shui)(shui)(shui)系統(tong)(tong),供水(shui)(shui)(shui)系統(tong)(tong)內是(shi)否(fou)(fou)(fou)有一定的(de)(de)(de)(de)水(shui)(shui)(shui)量(liang),控(kong)(kong)(kong)制(zhi)(zhi)加(jia)(jia)濕(shi)(shi)(shi)(shi)(shi)鍋爐(lu)水(shui)(shui)(shui)位(wei)(wei)的(de)(de)(de)(de)水(shui)(shui)(shui)位(wei)(wei)控(kong)(kong)(kong)制(zhi)(zhi)是(shi)否(fou)(fou)(fou)正常,加(jia)(jia)濕(shi)(shi)(shi)(shi)(shi)鍋爐(lu)內的(de)(de)(de)(de)水(shui)(shui)(shui)位(wei)(wei)是(shi)否(fou)(fou)(fou)正常。如以(yi)上(shang)(shang)(shang)一切都正常,那就(jiu)要(yao)檢(jian)查(cha)電器(qi)(qi)控(kong)(kong)(kong)制(zhi)(zhi)系統(tong)(tong),這要(yao)請(qing)專(zhuan)業維修人員進行(xing)檢(jian)修。東(dong)莞市(shi)科文(wen)試(shi)(shi)驗設備有限公司(si)專(zhuan)業維修小(xiao)型(xing)恒溫(wen)(wen)恒濕(shi)(shi)(shi)(shi)(shi)箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang),可(ke)程(cheng)式(shi)恒溫(wen)(wen)恒濕(shi)(shi)(shi)(shi)(shi)試(shi)(shi)驗箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang),高(gao)(gao)低溫(wen)(wen)濕(shi)(shi)(shi)(shi)(shi)熱(re)試(shi)(shi)驗箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang),交變濕(shi)(shi)(shi)(shi)(shi)熱(re)試(shi)(shi)驗箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang),濕(shi)(shi)(shi)(shi)(shi)熱(re)老(lao)化試(shi)(shi)驗箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang),溫(wen)(wen)濕(shi)(shi)(shi)(shi)(shi)度試(shi)(shi)驗箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang),高(gao)(gao)低溫(wen)(wen)試(shi)(shi)驗箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang),高(gao)(gao)低溫(wen)(wen)老(lao)化箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang),冷(leng)(leng)熱(re)沖(chong)(chong)擊測試(shi)(shi)箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang),小(xiao)型(xing)冷(leng)(leng)熱(re)沖(chong)(chong)擊試(shi)(shi)驗箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang),大(da)(da)型(xing)冷(leng)(leng)熱(re)沖(chong)(chong)擊試(shi)(shi)驗箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang),三箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang)式(shi)冷(leng)(leng)熱(re)沖(chong)(chong)擊試(shi)(shi)驗箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang),高(gao)(gao)溫(wen)(wen)老(lao)化箱(xiang)(xiang)(xiang)(xiang)(xiang)(xiang)等(deng)。

Contact Us
  • 聯系手機:(微信同號)
  • 聯系QQ:1908114701
  • 聯系郵箱:
  • 聯系電話: 83819138
  • 聯系地址:東莞市常平鎮橋瀝馬屋新村二街53號

掃一掃  加關注

掃碼獲取報價方案

©2023 廣東科文試驗設備有限公司 版權所有  備案號:    GoogleSitemap

主營:高低溫測試箱,濕熱老化試驗箱,快速溫變箱,氣候模擬試驗箱,冷熱沖擊箱,溫度循環試驗箱

聯系電話:

掃一掃,微信咨詢